Heavy rain and flash floods on site: what MOM's adverse weather guidelines advise

Stop work in tunnels, basements and excavations not adequately protected against flooding, use official alerts, and check the site before restarting.

By HeatAware teamUpdated 4 min read

Heavy rain worksite safety starts with a plan made before the rain. The Meteorological Service Singapore (MSS) says the wet phase of the Northeast Monsoon usually runs from December to early January. In that phase, monsoon surges can bring widespread, continuous moderate to heavy rain.

This guidance is for site managers, supervisors and safety officers.

Guidelines backed by WSH Act duties

On 4 April 2025, MOM and the WSH Council introduced the WSH Guidelines on Preparing for Adverse Weather. They cover strong winds, heavy rain and floods, lightning, heat stress and haze. The guidelines are not mandatory, but employers and workers still have duties under the Workplace Safety and Health (WSH) Act. MOM has said it will take enforcement action against those responsible for safety lapses. Heat stress and haze also have separate MOM measures, some of them mandatory.

Under the Act, employers must take reasonably practicable steps for the safety and health of their workers, including emergency procedures. Principals and occupiers have duties too, and workers must follow the safe work procedures in place.

Tunnels, basements and excavations

Tunnels and basements may flood in heavy rain. Excavation pits may collapse from heavy rain or rapid water infiltration. For these areas, the guidelines advise:

In heavy rain, if a tunnel, basement or excavation pit is not adequately protected against flooding, stop work and evacuate all workers in it immediately.

The guidelines also advise stopping outdoor work once thunder is heard or lightning is seen. See lightning and outdoor work for where to shelter.

Getting warnings in time

MOM and the WSH Council recommend subscribing to heavy rain and flash flood alerts. The guidelines also say MOM will inform workplaces as early as possible before adverse weather. Once alerted, workplaces should put their response plans into action and keep track of conditions.

AlertRun byWhat it tells you
Heavy rain warnings by SMSMSSHeavy rain expected, usually about 15 – 30 minutes ahead
Flood Alerts channel on TelegramPUBUpdates on potential flood risks
myENV appNEAAlerts on heavy rain, flash floods and drain water levels
Water-level SMS alertsPUBWater in a chosen canal or drain rising above 50%, 75%, 90% and 100% of its depth, for up to 3 stations

To prepare: a warning about 15 to 30 minutes ahead leaves little time. Decide in advance who receives each alert, how they pass it on, and which work stops first.

Before the rain

The guidelines recommend assessing how adverse weather could affect your site and work, then setting a response plan to match. Our guide to putting heat stress into your risk assessment shows the method. The guidelines also recommend:

  • Stabilise the ground, for example with proper shoring, to prevent soil movement.
  • Tie back temporary structures so floodwater cannot wash them away.
  • Keep an adverse weather kit, such as torches, rain suits, rubber boots, sandbags, a water pump and a first-aid kit.
  • Keep response equipment ready, such as first-aid kits, AEDs and rescue equipment.
  • Set notification procedures, with backup communications such as walkie-talkies or loudspeakers.
  • Train and drill workers on the plan, and share it with your contractors.

A simple way to keep the plan running is to add it to your heat stress management programme.

After the rain

The guidelines set out these steps before work restarts:

  1. Drain waterlogged areas.
  2. Re-assess ground stability.
  3. Check that machinery and equipment are safe. Do not operate anything that is damaged or in poor condition. You can ask the supplier or manufacturer for a checklist.
  4. Train workers on flood hazards in the recovery phase, such as electrical hazards.
  5. Do not resume if conditions are suspected to be unstable or unsafe.

Workers should report unsafe conditions to their supervisors immediately.

PUB's flood tips for the public are worth sharing with your crew. Keep out of flooded areas and stay on high ground. Avoid touching electric switches or appliances when wet or standing in water.

Frequently asked questions

Should excavation work stop during heavy rain?

Yes, unless the excavation is adequately protected against flooding. The guidelines warn that excavation pits may collapse from heavy rain, and advise stopping work and evacuating all workers in them immediately.

How much warning do heavy rain alerts give in Singapore?

MSS says its heavy rain warnings are usually issued about 15 to 30 minutes before heavy rain. PUB's canal and drain water-level SMS alerts give a separate warning as the water rises.

When can work resume after a flash flood?

Once the site has been checked. The guidelines say to drain waterlogged areas, re-assess ground stability and make sure machinery and equipment are safe. Work should not resume if conditions are suspected to be unstable or unsafe.


General guidance based on the WSH Council and MOM's WSH Guidelines on Preparing for Adverse Weather, MOM's summary and press release, the MSS FAQ and Climate of Singapore pages, NEA's myENV page, and PUB's Get Flood-Wise and SMS alerts pages. Always check the latest official guidance.

heavy rainflash floodsadverse weatherWSH Counciloutdoor work